Attributes
Attributes
We have just upgraded to Creo 2 (from wildfire 5) and are having issues connecting to our Windchill server on start up. We have Windchill 10.0 M040 and Creo 2 M090.
We Log into Creo 2 the first time, set up the server details using server manager. The second time we log in all is well, server has connected and we can see and use the workspaces. The third (and any subsequent log ins), the server has disappeared from the list of servers, and we have to manually log in again.
Windchill works fine in an IE browser.
I have deleted the .wf file in my appdata/roaming/ptc/proEngineer/Wildfire folder, and deleted the 2.3 file in appdata/local/ptc/creo/platform folder as instructed by our USA counterparts, but to no avail.
I recently added some custom attribute mapping in Desktop Integration per the instructions in document CS36657 (http://sv-hou-cadls01.cjes.local/Windchill/app/#ptc1/tcomp/infoPage?oid=OR%3Awt.doc.WTDocument%3A135716&u8=1)
It sort of works, but when mapping the "creator" attribute from Windchill to the "Created By" attribute in Office, the username (e.g. - bsmith) is what is displayed in the Office document. I would rather the full name of the creator be displayed (e.g. - Bob Smith).
Does anyone know of a way to map the Fullname field of the creator attribute to Office instead of the username field?
Any help is appreciated.
Thanks,
Joel
Is there a way to get like a full system report if there are any differences between the Name and Number of an item?
We are using Windchill 10.0 M030 and most of our items are matched up, but a few of them have contradicting Names and Numbers. I would like to know if there is a way to get a list of all the items with discrepancies?
Attached it what I am looking at trying to match up.
Thanks for any help!
I have a product team as in snapshot-
for change admin II role in a team I have added a group called CM as an assignee.
how can I get the this group from product using code
And also in general how to get a particular role and respective particiapants in a team (specific to a product)
Hi All,
I am wondering what the correct Java build should be used with Windchill 10.1 on client machines running Windows 7 64bit.
We are using Creo 2.0 M080 with Windchill 10.1 M040.
There are some users that are losing connection and some work is not being saved properly. This is leading to a mismatch in cache data between the Server Workspace and the Client Workspace.
We are not sure if this a Java issue but trying to check different avenues where an error may occur.
Thank you.
Brian
Does anyone know how to change the Name attribute of a soft type to a drop down list instead of a line to type on? I changed the attribute to have an Enumerated Value List, Selection List Style to Drop Down and Input Field Type to Single Line. I stopped and started my server and no change. I am on 10.1 m040. We want to control what names can be picked for a soft type document.
Thank you,
Brian
we are using creo parametric 2.0 but cand not purge any folder our system Windows 7 64 bit how to purge or subpurge folder.
I am pleased to announce the general availability of the PTC System Monitor (PSM) release 3.0 F000.
This new release introduces many new enhancements making it easier for you to monitor, diagnose and service your PTC applications. Below is a list of the key highlights, for more details please see the What’s New guides:
PSM 3.0 also adds support for Servigistics Service Center, extending similar monitoring and troubleshooting capabilities currently offered to Windchill PDMLink, Windchill ProjectLink, FlexPLM and Integrity products.
The following information provides details on how to download the latest version of the PTC System Monitor, the latest documentation, access technical support, PSM Central Page, and how to provide non-support based feedback.
Download
Download the PTC System Monitor release 3.0 F000 using the following steps.
1. Navigate to the PTC “Download Software Updates” page.
2. Click the “Order or Download Software Updates” link.
3. Click WINDCHILL PDMLink,WINDCHILL ProjectLink, Integrity, FlexPLM or Servigistics Service Center
4. After downloading the ZIP file, unzip it and follow the installation instructions in the PTC System Monitor Installation and Deployment guide.
Documentation
Use the links below to access common PTC System Monitor documentation:
PTC System Monitor What’s New - Integrity
PTC System Monitor Product Compatibility Matrices
PTC System Monitor Known Issues
For product specific installation and usage documentation access the links below:
PTC Windchill PDMLink and ProjectLink
PTC System Monitor Installation and Deployment Guide
PTC System Monitor Administration and Usage Guide
PTC Integrity
PTC System Monitor Installation and Deployment Guide
PTC System Monitor Administration and Usage Guide
PTC System Monitor Quick Upgrade Steps – Integrity
PTC Windchill FlexPLM
PTC System Monitor Installation and Deployment Guide
PTC System Monitor Administration and Usage Guide
Servigistics Service Center
PTC System Monitor Installation and Deployment Guide
PTC System Monitor Administration and Usage Guide
Support
Please contact PTC Technical Support for all technical questions related to the PTC System Monitor:
800-477-6435 |
PTC System Monitor Central page
Link below offers additional information and resources on the PTC System Monitor
Feedback
Email the product management team at:
Manager PTC Product Management | VP PTC Product Management |
Thank You
Hi.
Is it possible to create ServiceListener for state change event?
I need to change object folder if object state accepts specified value.
Can anyone provide java code solution?
Thanks.
I am installing WBR 10.2 on existing 10.1 machine.
I have 2 machine,the machine where I am installaing contains only previuos 10.1 reporting folder and parts link server.
I am getting error while installing WBR 10.2,related to path .
n existing installation of Windchill Business Reporting has been detected in D:\ptc\Windchill_10.1\Reporting. A new installation of Windchill Business Reporting cannot be performed until the existing installation is uninstalled and the machine is rebooted.
Please help me.
How can I download representation and annotation of a WTDocument in Windchill using java or a task.xml (webject)?
I need to download these files to create another WTDocument and reference it to the original Document, creating the verification copy.
Thanks in advance
Hi.
I need to find WTPartUsageLinks by child part. Can anyone provide java code to construct QuerySpec?
Thanks.
Hi
It´s my first intervention in a Windchill forum and i hope someone can help me.
I have Windchill 10.1 configurated for publishing PDF files whenever we do checkin or create a representation.
<?xml version="1.0"?>
<rules evaluate-rules-on-republish="true"
xsi:schemaLocation="http://www.ptc.com PublishRulesSchema.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.ptc.com">
<authoring-application name="PROE">
<additional-files name="standard_files">
<!-- only default='true' files will be generated at this time -->
<file output-prefix="pdf" default="true" type="dxf" display-label="PDF"/>
</additional-files>
<publish additional-files="standard_files" on="checkin"/>
<publish additional-files="standard_files" on="create-representation"/>
</authoring-application> </rules>
this works pretty well, but we have somes drawings whit 2 sheets, and in those cases, Windchill creates a PDf with two pages. What i want to know is if there's a way of creating only the first sheet in PDF.
thanks in advance
Hi.
Is it possible to add Standard or Global attribute fro WTUser?
In my case only Alias and Calculated are available.
Thanks.
Hi.
I have soft type of WTPart and soft type of WTPartUsageLink.
How can i specify my link soft type while adding one part to structure?
I cann't create relationship constraint for my link soft type, only for WTPartUsageLink. Where and what do i need set in settings to enable this option?
Thanks.
PTC is currently considering an enhancement to the build process to allow an attribute in the CAD Document Uses Link Soft Type to be mapped to either the WTPart Usage Find or Line Numbers.
From a dev perspective, it would be much cleaner to require:
Requiring this means that the build process (and thus check in of the CAD Document) would never fail due to value/type mismatch.
However, we (PMs) are wondering if that would be too restrictive.
Do you currently populate Assembly Drawing Balloons or BOM Balloon numbers to an attribute?
Do you know what type (i.e. integer, string, other) of attribute is being used?
Thanks for your feedback.
Jennifer
Would anyone like to share real world uses for these links (what type of data and why you choose the link you do)? I have read PTC definition and the definition on this site...still kind of foggy. I understand Owner and Calculated (easy), but the others....? Lets say I have a fixture that I want to asociate with a part that uses that fixture, what link would I use to represent that? This would help with down stream notification of what fixfture to use and for the engineer to know when revising that they need to look at changing the fixture to match the new part version.
HI guys,
hope someone can give me a hint with my Circuitworks problem.
Our company try to use circuitworks with windchill.
Circuitworks use like Toolbox a own database, so whats the difference between toolbox and circuitworks?
With the new functionality in Windchill 10.2 – SolidWorks Workgroup Manager “Windchill File System” we can use the circuitworks parts in windchill but Windchill don't recognize them as toolbox parts.
The circuitworks parts are in the toolbox folder and we run the toolbox properties executable.
The parts are marked correct as toolbox parts but windchill don't reuse the parts who are already checked in.
so... The question is, when is for windchill a part = toolbox part? How realize windchill when to reuse the library parts and when not?
greetings marcos
Hi.
How can i get data from wizard component builder to use it in wizard step jsp by javascript?
I construct tree for wizard step and build some log message during it. Next i need to use this log message in afterJS function specified for this wizard step.
Is it possible?