Hi Can any one help how I can associate WTPart with EPMDocument
Hi Can any one help how I can associate WTPart with EPMDocument
parts/asm cannot be retrieved
hi
I am having trouble retrieving data from windchill, followed by the massages bellow :
1. The object with the following key was deleted or inaccessible: "wt.epm.EPMDocument
2. Local cache for source "failedRequest" is having incomplete information for merge
3. Local cache contents need to be synchronized with the workspace
does enyone have en idea what could be the problem and how to fix this?
Changing the preference at library leval
Hello,
Is there any way to chnage the preference at library leval using loadfiles?
I woudl like to have the preference "Yes" for some of the library and "NO" to some of the libraries.
Thank you in advance..
What is your best practise for the handling of objects which have to be deleted?
How do you handle objects in PDMLink which have to be deleted in the daily business?
The standard user can´t (and shouldn´t) delete those objekts
We thought about a folder in every content which is purged regulary.
Does somebody have experience with that or better solutions?
How to convince designers to use auto numbering ?
In our current setup we generate a unique auto-numbered filename and document number for CAD documents created in Creo. The number is generated by Windchill but the designer can override this to organize client-specific assemblies and drawings. From my point of view, generic models that are not related to that specific product should have that initially generated number.
Some designers have convinced their engineering manager that with auto-numbering and no logic in that number, it is almost impossible to save copies of the models since there is no indication if a model has te be reused or not. Furthermore, our production department is very much organized by the part numbers, but we've made some important steps to start moving away from that principle. Engineers who are eager to return to a fully manual numbering are hereby rendering our efforts obsolete and have sometimes very little interest for what ERP, reusability, ... concerns.
The advantages of automatic numbering are clear to us however, but it it appears not that easy to convince everybody. I post this question because I hope to get some input of anybody who responds with "Hey, we've managed to do this, without reverting to physical violence...". I reallty like to hear how you got this through.
Best regards,
Steven
Windchill 10.1 IndexQueue Errors
Went into the Queue Management utility and noticed that we have the following "severe" Errors:
1) wt.queue.QueueWatcherMBean.exceededTotalEntriesThreshold
2) wt.util.WTException: Error processing collection
Can anyone provide information or solutions regarding the above errors?
Thanks
Adding IBAs in Windchill for ModelCHECK
To all ModelCHECK users,
I am trying to implement ModelCHECK and follow the instructions of adding the instance -based attributes into Windchill....
Although the Gatekeeper documentation says to add these, it does not define specifically where. I am ASSuming that it means under Site>Utilities>Type and Attribute Manager, select CAD Document, then add the following MODEL_CHECK (string), MC_ERRORS (integer), and so forth. It states in the documentation that these need to be "mapped" to the parameters of parts, assemblies, drawings. Ok i think I get what this means....turn on the param creation of these parameters in modelcheck config and they will match up to the IBAs once you try to check them in??? Is that not an easier way to explain this cuz it confuses the hell out of me how they over engineer the technical language in these documents sometimes...any help would be appreciated to clarify.
Thanks,
Buddy
Pulling Rev out of Windchill to display in title block of drawing
I would like to change our formats (title block table) to display the proi_revision in the REV box instead of manually typing in the current rev. Does anyone do this, are there any issues that we might encounter in the future?
Login Authorization Failed Error
I'm trying to change the URL of my Windchill by doing reverse proxy of Apache. I'm reffering WCAdv Deployment guide and also
this thread http://communities.ptc.com/thread/34430.
I have completed all the steps and after restarted all the services.Then when I try to access windchill
with my new URL it is showing Login Authorization failed error.But it didn't asked for username,password.
Am I missing something?I have attached the image for my error.I need your help and suggestions.
Rename of several independent objects
Hello,
As a feedback from customers I am frequently asked why it is impossible to rename several independent objects in 1 action in Windchill PDMLink.
I know it is possible to use the collector to gather required dependent objects of an assembly and, thus, being able to rename several objects, but it is for now IMpossible to rename a bunch of objects that have no relationship to one another.
I know this is common functionality in Pro/INTRALINK 3.x, but not in Windchill unfortunately. In Windchill, it is only possible to rename ONE object at a time. Renaming several object can become a burden.
Anyone?
Auto-Update Workspace
Hey community,
I was wondering if there is a way to auto update my workspace with commonspace. So that i dont have to update all the time.. Maybe like a configuration where i can set it to every 10 mins or so?
Thanks,
Brock
Windchill Desktop Integration - New Office Toolbar Coming in 10.2_M020
Hi,
PTC has been busy working on an update to the Windchill Desktop Integration ribbon interface in Microsoft Office. The current ribbon implementation has been in place for a long time and looks like this. It uses standard ribbon buttons with text labels. These text labels are a bit large and verbose, making the overall layout of the ribbon very wide as shown by the collapsed Local File Actions panel.
![]() |
The objective of the redesign was to make the ribbon easier to use, by presenting the most commonly used actions with large icons in a compact manner that will reduce, if not eliminate the need to collapse the action panels. We accomplished this by implementing the Microsoft ribbon Split button which allows us to put the most commonly used actions directly on the ribbon and the secondary actions below in a drop down menu.
The new ribbon UI in Microsoft Office looks like this.
Hopefully you'll find this new layout much easier to use and folks will have much fewer questions regarding the use of the various actions in the Microsoft Office Windchill ribbon.
Windchill 10.2_M020 Provides Native Drag-n-Drop File Upload Options
Hopefully everyone has seen the videos covering the new drag-n-drop capabilities coming with Windchill 10.2_M020. If not, click on the video tab and look for the following videos. They do not have audio, but they give a clear understanding of how the drag-n-drop functionality is implemented.
- Windchill 10.2 Drag-n-Drop Single Document Upload
- Windchill 10.2 Drag-n-Drop Multiple Document Upload
- Windchill 10.2 Drag-n-Drop Multiple Attachment Upload
What changes this in 10.2_M020, is a change to the default value of the Attachments preference named "File Upload Mechanism". It has always been set to "Use Java applet functionality to select and upload files" and now it will be set to "Use basic browser functionality to select and upload files". If the browser supports HTML5, the drag-n-drop functionality will work automatically.
If after upgrading your system to 10.2_M020, the drag-n-drop capability is not working, double check the value of this preference and ensure your browser supports HTML5. I have done all my validations with Chrome and Firefox but still need to test IE 10 since my machine is still on IE 9.
-Scott
Notification
Hi All,
Is there any way we can monitor notifications whether they are reaching the concerned persons or not?
Thanks in Advance
Varun.
ADD TO WORKSPACE
Our company has recently moved to Windchill 10.0 and the toolbar in my workspace has a green plus sign to add to workspace. How does this work? Our version states that you have to have an item chosen before adding to workplace. Why do I have to search for the component and then have to add it? This is a backward step from the previous version.
Possibility of exporting all CAD files from Windchill in one shot
Hello Guys,
I have a requirement where I want to export a long list assemblies from windchill to local computer.
Steps I follow,
- Search for assembly number,
- Add to workspace,
- Export from workspace to local drive,
As you can see, this way is not feisable for a list of assemblies.
So, i want to export the whole set of data (CAD files) from Windchill at once.
Is this possible?
If I understand right, we cannot get the dump from Windchill server as the files are encrypted (Not sure).
Any suggestions will be greatly appreciated.
Thanks in advance!
Rajesh Jaganatha
PTC Windchill 10.2 M010 Part Structure view
Upgraded a testing environment to 10.2 M010 to test using process plans from the structure view of a Part, but do not see it there. Anyone using this new feature? Is there config that needs to be in place to enable this functionality? Thanks.
Windchill PDMLink Automatic Start and Stop
Hi Guys,
i am using windchill pdmlink 10.1 m040. i want to make batch files to automatically start and stop all windchill services. kindly send me the scripts exactly.
thanks
edit process template in trouble
Hello I have a big problem about edit a wfprocess template.
Its display warn view in my computer.
What can I do to fix this prolblem!?
DataUtility for enable/disable input field
Hi.
I need to configure ColumnConfig in my tree thus so that some rows have editable textfield, and only empty labels in others.
As far as i know this problem can be solved by setting DataUtility for ColumnConfig.
The question is what GuiComponent should i use?
Thanks.