Quantcast
Channel: PTC Community : Discussion List - Windchill
Viewing all 5797 articles
Browse latest View live

工作区笔记本附件文件下载提示签名过期

$
0
0

wt.wrmf.transport.WTTransportException: 来自 "http://ma700.ptc.com/Windchill/servlet/WindchillGW" 的签名, 签在 "Thu May 12 06:15:22 GMT 2016" 上, 接收在  "Thu May 12 06:26:14 GMT 2016" 上, 它已经被使用。 请重试该操作。如果继续发生该错误,请与系统管理员联系。

 

 

 

 

2016-05-12 14:26:14,931 INFO  [ajp-bio-8010-exec-1] wt.system.err wcadmin - java.io.IOException: Server returned HTTP response code: 500 for URL: http://ma700.ptc.com/Windchill/servlet/WindchillGW/wt.fv.master.StandardMasterService/doDirectDownload/actions%E8%8F%9C%E5%8D%95%E5%A4%87%E4%BB%BD_%E5%88%9B%E5%BB%BA%E4%BC%9A%E8%AE%AE%E4%B8%BB%E9%A2%98%E5%92%8C%E5%88%9B%E5%BB%BA%E4%BC%9A%E8%AE%AE%E7%BA%AA%E8%A6%81.xml?folderId=1230236&ft=RF&userid=11&adId=1962767&fileName=00000000083fbb&refsize=902&mime=text/xml&mk=wt.fv.master.StandardMasterService&ofn=actions%E8%8F%9C%E5%8D%95%E5%A4%87%E4%BB%BD_%E5%88%9B%E5%BB%BA%E4%BC%9A%E8%AE%AE%E4%B8%BB%E9%A2%98%E5%92%8C%E5%88%9B%E5%BB%BA%E4%BC%9A%E8%AE%AE%E7%BA%AA%E8%A6%81.xml&c=0&riid=-1&sT=1463033722&sign=udnRZtLet7BvYOHwcQIYWA%3D%3D&site=http%3A%2F%2Fma700.ptc.com%2FWindchill%2Fservlet%2FWindchillGW&AUTH_CODE=HmacMD5&isProxy=true

2016-05-12 14:26:14,936 INFO  [ajp-bio-8010-exec-1] wt.system.err wcadmin -  at sun.net.www.protocol.http.HttpURLConnection.getInputStream(HttpURLConnection.java:1626)


Generic Picker Callback

$
0
0

Generic picker callback method does not get the oid of the object selected. I have generic picker in the jsp that would select the document and call a callback method. I am trying to get the oid of the selected object but it throws error.

Package creation to include iges and step files

$
0
0

I have been playing with packages with the intent to use these with suppliers.  I currently have Windchill publishing iges and step files of all our parts and assemblies.  When I tell the package to include iges and step none are there.  I have tried include and exclude methods.  We are on 10.2 m020.

Windchill 10.2 services start/stop best practices?

$
0
0

Hello,

 

 

I'm finding recommendations and installations that are all over the map with regard to this, Being accustomed to products that have rigid requirements for service stop/start order, I was looking for feedback.


For a standard non-clustered machine, I was using these orders for stop/start with machines in my test environment (taken from PTC documentation or a document, I didn't note the source):

 

Stop order: Windchill, Windchill Directory Server, Apache
Start order: Windchill Directory Server, Apache, Windchill

 

Then I run across a live installation configured by someone with a more time and experience with the product using this order for a backup script:

 

Stop order: Windchill, Apache, Windchill Directory Server

Start order: Windchill Directory Server, Apache, Windchill

 

What I would like to know is if there is a best practice based on the technical needs, structure and/or interaction of the Windchill services.  I've read the older discussions here with previous Windchill releases, and it seems reasonable to stop or start the Apache services depending on how users could be affected. Other than that, how should the Windchill service and the Directory services be handled?

Thank you.

 

Regards,

 

ML Starkey

Windchill Server Domain name change.

$
0
0

We have changed our Windchill Server domain name from df-wc-test.hs.local to df-wc-test.dfinc.hs.com.  Updating the Repository entries, Web Server host name entries, Windchill entries and Directory host name server entries will work? Please let me know if there are any additional steps to be performed.

A pop-up to denote the preference that has to be change while disconnecting/uninstalling DTI

$
0
0

Connecting to Windchill DTI changes the download mechanism preference to "Windchill DTI". But disconnecting/Un-installing DTI, does not change the preference to default.

 

Need  to configure the auto preference change back to normal or an alert box denoting to change the preference manually.

How to Create PrjPCM file in Altium

$
0
0

Hi I have one ugrent requriment

 

How I can create Project file (PrjPCB) in altium and once I create it with multiple schematic I want to Map it with Windchill BOM so how I can create the BOM in Windchill so it can associated with Project file

 

Please let me know if any one has steps

Unable to register Creo and Auto CAD with PDM Essentials 10.2 M030

$
0
0

Hi all,

 

I'm trying to integrate Creo 3.0 M080 and Auto CAD 2016 with Windchill PDM Essentials 10.2 M030 (CPS13) but getting error " Invalid server location".

We've Windchill url like abc.xyz.com:81/Windchill. We're using port 81 for web server.

We're able to access windchill through browser with out any problem but  unable to do CAD integration.

I'd like to mention that we're not using VPN to access Windchill server and default browser for Creo is IE.

Kindly help me out.

 

Regards,

Krishna Chaithanya.


Coloring of restricted substances over threshold in excel material content report

$
0
0

Many of our customers want to know why a component is failing for a particular regulation and demand to indicate the failed substance in the material content report. At present it is required to search the MPN individually and click on the fail(X) symbol and the system shows the result.

 

Since this validation functionality and information exists in the system database somewhere it might by an easy development task to include this feature in report.

PTC Pro/INTRALINK 10.2 Oracle 12.1.0.2 M030; where to find it?

$
0
0

Simple question:

 

Where do I find this download?

The PSI installer says I need in my staging area.

I've looked through all the downloads for PDMLink 10.2, PRO/Intralink, PRO/Intralink Access and PRO/Intralink Single Site sections of the down load page.
All I can find it the Oracle Software Assistant.

pro-intralink-oracle.JPG

 

Thank you.

 

Regards,

 

ML Starkey

java.lang.Exception: deploy failed for (ie) with return code = 1

$
0
0

Hello,

I get this error java.lang.Exception: deploy failed for (ie) with return code = 1 >

 

 

when trying to install Windchill PDMLink 11.0. on to a Windows Server 2012 Std R2 64Bt OS. Can some one help.

 

Thanks,

Ming

 

PTCSOLNINSTALLER_PtcInstall

LOG:

 

INFO   2016-05-09 16:27:30 - 

INFO   2016-05-09 16:27:30 - Total time: 30 seconds

INFO   2016-05-09 16:27:30 - Java HotSpot(TM) 64-Bit Server VM warning: ignoring option MaxPermSize=256M; support was removed in 8.0

DEBUG  2016-05-09 16:27:31 - Installation is Aborting.  The installation cannot continue.

DEBUG  2016-05-09 16:27:31 - 正在中止安裝。 無法再繼續安裝。

 

FATAL  2016-05-09 16:30:32 - Aborting installation.

FATAL  2016-05-09 16:30:32 - 正在中止安裝。 無法再繼續安裝。

 

FATAL  2016-05-09 16:30:32 - java.lang.Exception: deploy failed for (ie) with return code = 1

FATAL  2016-05-09 16:30:32 - aborting: original exit_code = 2

FATAL  2016-05-09 16:30:32 - aborting: normalized exit_code = 2

DEBUG  2016-05-09 16:30:32 - SHUTDOWN REQUESTED

DEBUG  2016-05-09 16:30:32 - (X) commiting registry

DEBUG  2016-05-09 16:30:33 - (X) shutting down service manager

DEBUG  2016-05-09 16:30:34 - (X) cleaning up temporary directories

DEBUG  2016-05-09 16:30:34 - Exiting with exit code: 2

DEBUG  2016-05-09 16:30:34 - java.lang.NullPointerException

DEBUG  2016-05-09 16:30:35 - cleanUp()

DEBUG  2016-05-09 16:30:35 - calling cleanUpWin32()

How do I get the PTC Windchill printer to work?

$
0
0

How do I get the PTC Windchill printer to work?  I try to print to a file, but I get an error message that says "Printer not activated, error code -30"

How to get list of Released objects(documents) in mail notification in promotion approval request?

$
0
0

Hi Gurus,

 

I have one customer requirement that, After approving the list of promotion objects, those object names, numbers and version should be included in a mail notification.

Kindly suggest if there is any work arounnd/customization code available for the same.

 

 

 

Regards,

Mahesh Kumar G

“Update Worker" for data managed in Windchill (e.g. Solidworks 2014 -> 2015)?

$
0
0

As Solidworks needs to convert files to the new file format after a major version upgrade to ensure performance and stability we thought about the need to have an “Update Worker” to convert at least the catalog parts to a new Solidworks version.

 

We thought about a queued processing with multiple workers just bringing up the files in Solidworks, save to UWGM Workspace and check-in with admin permissions including a comment that there should be no change to the geometry.

Has anybody done something similar already?

How to ensure to touch a file only once if it is used in multiple assemblies and added to the queue as a standalone part as well?

 

Any help would be appreciated,

Stephan

info*engine implementation how to do , i am newbe in plm as well as windchill

$
0
0

info*engine  implementation how to  do , i am newbe in plm as well as windchill


Publish Rules

$
0
0

 

Hi all,

 

I was reading the documentation on Publish Rules in the Visualization services guide.

 

I have few questions.,

 

1. Looks like the publish rules are only for EPMDocuments, is this true?

 

Regarding the trigger for publishing. the documentation says.,

 

 

There are five values that will trigger Publish Rules processing:

• <publish on=”checkin”/> — the trigger for Publish Rules evaluation is a

publish job for an EPMDocument resulting from a check-in.

• <publish on=”create-representation”/> — the trigger for Publish Rules

evaluation is a publish job for a Create Representation action (via the New

Representation wizard) executed from an EPMDocument (or its ownerassociated

WTPart) from the Representations/Annotations table.

• <publish on=”schedule”/> — the trigger for Publish Rules evaluation is a

publish job for an EPMDocument resulting from a job submitted using the

WVS Job Scheduler.

• <publish on=”unknown-source”/> — the trigger for Publish Rules

evaluation is a publish job resulting from any other event, such as from a

manual republish, republish on change, workflow initiated (doPublish),

etc.

• <publish on=”manual-post”/> — specifies that a matching EPMDocument

can have manual post-publishing

 

Is there any trigger for Publish on "PDM Checkout"? Because OOTB ,when the carry forward is turned off, it also disables publishing when "PDMCheckout".

 

I have a related post here...

 

publish.copyrepresentationsforward

 

Any suggestions on how to handle this requirement? (Customization is the last option for me).

 

Thanks

Hari

Search from excel to PDMlink

$
0
0

Can we connect a link between excel and pdmlink.  .. ? I am working on a specific project, where i want to search  available items in PDMlink from excel which is stored locally .. ?

Change process and Workflows

$
0
0

Hi All,

 

Being a beginner in windchill, I would like to know about Workflows and Change Process in detail.

 

Thanks,

Riyaz.

Windchill 10.2 services start/stop best practices?

$
0
0

Hello,

 

 

I'm finding recommendations and installations that are all over the map with regard to this, Being accustomed to products that have rigid requirements for service stop/start order, I was looking for feedback.


For a standard non-clustered machine, I was using these orders for stop/start with machines in my test environment (taken from PTC documentation or a document, I didn't note the source):

 

Stop order: Windchill, Windchill Directory Server, Apache
Start order: Windchill Directory Server, Apache, Windchill

 

Then I run across a live installation configured by someone with a more time and experience with the product using this order for a backup script:

 

Stop order: Windchill, Apache, Windchill Directory Server

Start order: Windchill Directory Server, Apache, Windchill

 

What I would like to know is if there is a best practice based on the technical needs, structure and/or interaction of the Windchill services.  I've read the older discussions here with previous Windchill releases, and it seems reasonable to stop or start the Apache services depending on how users could be affected. Other than that, how should the Windchill service and the Directory services be handled?

Thank you.

 

Regards,

 

ML Starkey

File Based Series : Remove Delimiter and increase the depth for versioning

$
0
0

Hi All,

 

I had created a series in this way as I had started a discussion regarding the same.

 

File Based Series : The series or seed is undefined

 

However I even wish to remove the delimiter say for suppose as upon revising or check out and check in it gets modified as V1.1 V1.2

So I dont want that delimter dot (.) to be there. I had seen the PTC Tech support portal for this and found few cases

 

Step 1.)

I went to wt.properties file and found the property. I made two modifications in wt.properties file

 

wt.series.HarvardSeries.delimiter=.

 

So I removed the dot and equaled it with nothing as

 

wt.series.HarvardSeries.delimiter=

 

Step 2.)

 

wt.series.HarvardSeries.depth=16

 

So I updated the depth as 99

 

wt.series.HarvardSeries.depth=99

 

But after this the method server failed starting which is showing an error like

 

2016-05-12 11:36:27,662 INFO  [main] wt.system.err Administrator - Error initializing wt.series.HarvardSeries

2016-05-12 11:36:27,701 INFO  [main] wt.system.err Administrator - java.lang.StringIndexOutOfBoundsException: String index out of range: 0

2016-05-12 11:36:27,721 INFO  [main] wt.system.err Administrator - at java.lang.String.charAt(String.java:686)

2016-05-12 11:36:27,723 INFO  [main] wt.system.err Administrator - at wt.series.HarvardSeries.readStaticProperties(HarvardSeries.java:1042)

2016-05-12 11:36:27,728 INFO  [main] wt.system.err Administrator - at wt.series.HarvardSeries.<clinit>(HarvardSeries.java:164)

2016-05-12 11:36:27,729 INFO  [main] wt.system.err Administrator - at java.lang.Class.forName0(Native Method)

2016-05-12 11:36:27,751 INFO  [main] wt.system.err Administrator - at java.lang.Class.forName(Class.java:171)

2016-05-12 11:36:27,752 INFO  [main] wt.system.err Administrator - at wt.series.Series.getClassForName(Series.java:309)

2016-05-12 11:36:27,752 INFO  [main] wt.system.err Administrator - at wt.series.MultilevelSeries.newMultiLevelSeriesFromSeriesName(MultilevelSeries.java:554)

2016-05-12 11:36:27,753 INFO  [main] wt.system.err Administrator - at wt.series.MultilevelSeries.newMultilevelSeries(MultilevelSeries.java:210)

2016-05-12 11:36:27,754 INFO  [main] wt.system.err Administrator - at wt.vc.VersionControlHelper.<clinit>(VersionControlHelper.java:141)

 

So how to remove the delimiter for the custom_series class that I had created.

 

Thanks in advance. Kindly let me know

 

Thanks and Regards,

Aditya Achanta

Viewing all 5797 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>