Read-Only Vault

Just did our production upgrade this past weekend (9.1 > 10.2 M020).  All good except one thing. The defaultsystemvault and defaultsystemfolder come up Read Only + after Windchill restart.  Can...

View Article


How to restrict the users from initiating a change request only on released...

How to  restrict the users from initiating a change request only on released (State) drawings?

View Article


How can I make to ALIAS attribute show correct data when mapping documetn has...

I have created an ALIAS attribute and it display the data duplicate so many times as iteracions I have about the document mapped.When you use the following syntax, the following results are the...

View Article

Image may be NSFW.
Clik here to view.

Solidworks publishing not working

Hi,  I import solidworks files using WWGM but the publishing/thumnail is not working. I already did the command in windshell xconfmanager -t C:\ptc/Windchill\codebase\wvs.properties -s...

View Article

Workflow routing based on an attribute.

I have a workflow for a WTReferenceDocument soft type object. I also have custom attributes for the object. Once the workflow has started, I would at some point like to route the workflow based on the...

View Article


Preferred Content Cache Site upload error from Creo 2.0 M110 to Windchill 10.2

Hello Community, Recently we went through an upgrade from Windchill 10.0 M020 to Windchill 10.2 M020. Every aspect and function was successfully tested post upgrade with one major failure : The ability...

View Article

Metadata of an attribute for windchill customization

Hi , Can someone help me to fetch metadata of an attribute using customization? Am using WC PDM link 10.2 M030. There is an attribute a custom attribute "Awarenesslist" on the subtype of "Managed...

View Article

documents are not opening properly in product view using Internet Explorer

Documents are not opening properly in product view using Internet Explorer, after opening a document in product view next windows opens but everything displays grey there. Anyone have any idea ?

View Article


How to pull all attributes of a TypeIdentifier

Hi , I have a subType of a WCType. I want to pull all the attribute of that TypeIdentifer suing WC customization ThanksRK

View Article


Hiding reference parts from e-bom and hiding the weight of reference?

Hey there! First of all we use M050 and 2.0 release.We're trying to hide part which i use only for reference on my assembly. We use some parts just for review but when i get e-bom report i don't want...

View Article

HOW TO SET THE Revisioning SCHEME IN WINDCHILL ?

Hi How to set Revisioning scheme in windchill ? We are not following ptc windchill default parameter to define revision in part template, Instead we are mentioning revision as paramater name in tempalte ?

View Article

How to manage family table in windchill

How to manage family table in windchill ? Part_number & part_name remains same for generic and instacnce . Only file name is differnt . When uploading it is showing error"cad part not unique" Pls...

View Article

Windchill Implementation

Dear All,                I want to implement Windchill PDMLink heavy user for data management and document management in a organization for 3 users with creo 3.0. i need help in planning and...

View Article


Clarifications needed in BOM Management using Windchill

Hi,   Good day to all. I have a situation that needs some advice on how to handle the same. We have been using Windchill for quite some time now. During our usage of BOM we have identified that the End...

View Article

The best way to temporary prevent users login in the Windchill environment

Hi,Need to perform some administering tasks and data altering on productive Windchill environment (but not cluster) that can take a few days. The users should be prevented to alter the system in this...

View Article


Image may be NSFW.
Clik here to view.

Comment lier entre Doc CAD Part et Doc CAD Drawing ?

Bonjour, Je travail avec Windchill 10.2 et CATIA V5,Le designer créé un CAD Part (dessin 3D) et CAD Drawing (Plan).Je voudrais savoir est ce que c'est possible de les liés les 2 Doc avec une seule...

View Article

How to define which layouts of all objects that contains some attribute

Hi! I need to delete some attribute (not IBA). And how can I difine layouts of all objects that contains some attribute?

View Article


Add a Custom Attribute to a specific task in Workflow

Is there an easy way to add a custom attribute only to a specific task in a workflow?  For example, in the OOTB Change Notice workflow there is an Audit task.  How would I add an attribute to this task...

View Article

Creo View 3.0 Lite Crash

Hello everyone, my we are preparing to migrate to Windchill 10.2. With this we are going to put Creo View 3.0 Lite as our preview. Creo View itself as a standalone programs works fine and stable. If...

View Article

PTC Windchill PDMLink licensing model on a network

Hi, I needed clarity on the licensing model for Windchill PDMLink. Especially on a network. Please help out.